Available System:
ADAC Single Head Genesys Analog Nuclear Camera
 |
 |
 |
 |
| Click on image to see larger version |
1)
1993 ADAC Single Head Genesys Analog Nuclear Camera
- Rectangular 3/8” crystal, 20” x 15”. Shielding for up to 400kev. 55 linear gain Photomultiplier Tubes. Image Correction Processor to perform Energy, Linearity and Flood Corrections. Gantry compact ring with motor controlled motions. Five motor controlled motions with individualized digital readouts. X-ACT robotics for automatic set-up of Gantry. Six preprogrammed gantry positions to minimize setup time. Non-cantilevered, all purpose 380 degree Spec and Whole body imaging table. Dual screen digital control console for acquisitions and Video P-scope. User definable Imaging Protocols, Patient Safety sensors built into each collimator. X-windows Processing Software with 32MB image memory; 1.44MB, 3.5 inch floppy disk drive; 150MB, 0.25 inch cartridge tape drive. SunOS 4.1.3 UNIX, PegasysX 3.34, Ethernet, TCP/IP and NFS. Pegasys clinical software programs, SPECT and Gated SPECT protocols. Sun 21” Processing Monitor, keyboard, mouse, UPS, Ivy Gate included.
2) Collimator
3) Collimator Exchanger
- A wide variety of optional collimators are available for all energies. The collimator exchanger is manual operation and supports up to four collimator cores. The system comes with one collimator cart that supports one collimator for transporting the collimator from the exchanger to the system.
4) Patient Handling System (Bed)
- The ADAC motorized patient bed supports a variety of patient weights and sizes – up to 180 KG (400 pounds), meeting the needs of a wide range of clinical applications. The low attenuation characteristics of the ultra thin pallets and the close proximity of the detector to the patient optimize study resolution. The patient bed lowers to a convenient 48.3 cm (19 inches) for easy patient access.
5) ECG Input
- TTL Signal Input
- 0 to +5 Volt
- Negative and Positive Trigger
6) ECG Gating
- Forward or Forward/Backward by Thirds Framing in Planar Mode
- Forward or Forward/Backward by Thirds Framing in SPECT Mode
- Buffered Beat Window
- Bad Beat Rejection
- Number of Frames per R-R Interval or Milliseconds per Frame
- Automatic or Manual Selection of Beats Acceptance Window
7) IVY 101 Patient Monitor
8) Best UPS
Total Price: TBD
Acceptance: Sales quote is good for 30 days.
Terms: Unless stated otherwise herein, purchase is subject to NCI’s standard payment and shipping terms: 20% down, 70% due upon delivery, 10% due on acceptance not later than 90 days after ship date. FOB NCI factory; prepay and add freight. Buyer to incur any applicable insurance costs.
|